Manual

Map Protocol Modes to Deye settings


Solarman or DeyeCloud (with new connection method):

 

Protocol Operation Work Mode GridCharge in TimeOfUse Time in TimeOfUse SOC in TimeOfUse

Power in TimeOfUse

Charge A (Amper) MaxSellPower
Normal   no yes 5%* 'Max Battery Discharge', if missing: 'Max Inverter Discharge' no change  
Charge   yes yes SOC% ChargeLimitW, if missing: 'Max Battery Charge', if missing 'Max Inverter Charge' no change  
Discharge SellingFirst, after finish: is changed to previous value no yes SOC% 'Max Battery Discharge', if missing: 'Max Inverter Discharge' no change

- 'Max GridSetpoint / Discharge (W)'

- If discharge must be slower to last whole hour then program calculate this value; After discharge is changed to prev value

DisableCharge   no yes 5%* -'Max GridSetpoint / Discharge (W)' change to 0, after finish: is changed to previous value  

 

(*) 5% can be change to other value - parameter 'Default MinSOC after discharge' in 'Discharge Plan'.

Price<0:

  • (optional): switch off 'SolarSell' + switch on 'MI export to Grid cutoff'
  • (optional): change LV1 to 270V, this causes disconnect from grid (off-grid). When Price<0 has finished then program setup LV1 to previous value

Generator:

  • On: Set GEN in TimeOfUser (only during Operation="Charge") + Set GenSOC to CurrSOC+1
  • PurchasePrice>LimitPrice: change LV1 to 270V (disconnect from grid to start generator) or set NoBatt

Others:

  • "Switch off peak-shaving during discharge battery to grid": switch off Peak-Shaving
  • "Change Mode to 'Zero Export To CT' during charge battery from grid": change WorkMode
  • "Input Limit (A)": Grid Peak Shaving (W)

 


DeyeCloud only (old, limited DeyeCloud API, depreciated)

 

Protocol Operation Work Mode GridCharge in TimeOfUse Time in TimeOfUse SOC in TimeOfUse Power in TimeOfUse Charge A (Amper) MaxSellPower
Normal   no yes 5%* Max Battery Discharge no change  
Charge   yes yes SOC% ChargeLimitW, if missing: Max Battery Discharge no change  
Discharge SellingFirst, after finish: is changed to ZeroExportToCT  no yes SOC% Sell Power, if missing: Max Battery Discharge no change

- 'Max GridSetpoint / Discharge (W)'

- If discharge must be slower to last whole hour then program calculate this value; After discharge is changed to 'MaxSellPower after 'Discharge''

DisableCharge   no yes 5%* -'Max GridSetpoint / Discharge (W)' change to 0, after finish: is changed to 'MaxChargePower after 'Disable battery charge'  

 

(*) 5% can be change to other value - parameter 'Default MinSOC after discharge' in 'Discharge Plan'.

Price<0:

  • (optional): switch off 'SolarSell' + switch on 'MI export to Grid cutoff'
  • (optional): change LV1 to 270V, this causes disconnect from grid (off-grid). When Price<0 has finished then program setup LV1 to previous value

Generator:

  • On: Set GEN in TimeOfUser (only during Operation="Charge")
  • PurchasePrice>LimitPrice: change LV1 to 270V (disconnect from grid to start generator) or set NoBatt

Others:

  • "Switch off peak-shaving during discharge battery to grid": switch off Peak-Shaving
  • "Change Mode to 'Zero Export To CT' during charge battery from grid": change WorkMode
  • "Input Limit (A)": Grid Peak Shaving (W)

SolarAssistant only:

 

Protocol Operation Work Mode GridCharge in TimeOfUse Time in TimeOfUse SOC in TimeOfUse

Power in TimeOfUse (**)

Charge A (Amper)
Normal   no yes 5%* -'Default Gridsetpoint after discharge (W)' no change
Charge   yes yes SOC% ChargeLimitW no change
Discharge SellingFirst, after finish: is changed to previous value no yes SOC% - 'Max GridSetpoint / Discharge (W)' no change
DisableCharge   no yes 5%* - 'Max GridSetpoint / Discharge (W)' change to 0, after finish: is changed to previous value

 

(*) 5% can be change to other value - parameter 'Default MinSOC after discharge' in 'Discharge Plan'.

Price<0:

  • (optional): switch off 'SolarSell' + switch on 'MI export to Grid cutoff'
  • (optional): change LV1 to 270V, this causes disconnect from grid (off-grid). When Price<0 has finished then program setup LV1 to previous value

Generator:

  • On: Set GEN in TimeOfUser (only during Operation="Charge")
  • PurchasePrice>LimitPrice: change LV1 to 270V (disconnect from grid to start generator) or set NoBatt